Replacing Projector Bulbs
Sharp LCD projectors' bulbs last about 2000 hours under normal circumstances, after which they turn themselves off permanently with a timer. When you replac the bulb, you have to also reset the timer to allow the new bulb to be recognized for its 2000 hours.
To reset a Sharp LCD projector's bulb
- turn of the power with the 1/0 toggle or red push-button switch
- pull the power cable out of the projector
- hold down the keypad butons for down and right arrows along with
<enter> button (and keep holding)
- plug in the power cable
- turn on the power
- press the On button
- release the three keypad buttons
- check the hours in the system menu
The buttons are inverted when the projector is hung from the ceiling, so if you're working on an XGE3500, they look like this: